AJP - Renal Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Renal Physiol 273: F625-F634, 1997;
0363-6127/97 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Layton, H. E.
Right arrow Articles by Moore, L. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Layton, H. E.
Right arrow Articles by Moore, L. C.

AJP - Renal Physiology, Vol 273, Issue 4 625-F634, Copyright © 1997 by American Physiological Society


ARTICLES

Nonlinear filter properties of the thick ascending limb

H. E. Layton, E. B. Pitman and L. C. Moore
Department of Mathematics, Duke University, Durham, North Carolina 27708-0320, USA. layton@math.duke.edu

A mathematical model was used to investigate the filter properties of the thick ascending limb (TAL), that is, the response of TAL luminal NaCl concentration to oscillations in tubular fluid flow. For the special case of no transtubular NaCl backleak and for spatially homogeneous transport parameters, the model predicts that NaCl concentration in intratubular fluid at each location along the TAL depends only on the fluid transit time up the TAL to that location. This exact mathematical result has four important consequences: 1) when a sinusoidal component is added to steady-state TAL flow, the NaCl concentration at the macula densa (MD) undergoes oscillations that are bounded by a range interval envelope with magnitude that decreases as a function of oscillatory frequency; 2) the frequency response within the range envelope exhibits nodes at those frequencies where the oscillatory flow has a transit time to the MD that equals the steady-state fluid transit time (this nodal structure arises from the establishment of standing waves in luminal concentration, relative to the steady-state concentration profile, along the length of the TAL); 3) for any dynamically changing but positive TAL flow rate, the luminal TAL NaCl concentration profile along the TAL decreases monotonically as a function of TAL length; and 4) sinusoidal oscillations in TAL flow, except at nodal frequencies, result in nonsinusoidal oscillations in NaCl concentration at the MD. Numerical calculations that include NaCl backleak exhibit solutions with these same four properties. For parameters in the physiological range, the first few nodes in the frequency response curve are separated by antinodes of significant amplitude, and the nodes arise at frequencies well below the frequency of respiration in rat. Therefore, the nodal structure and nonsinusoidal oscillations should be detectable in experiments, and they may influence the dynamic behavior of the tubuloglomerular feedback system.


This article has been cited by other articles:


Home page
Am. J. Physiol. Renal Physiol.Home page
W. A. Cupples and B. Braam
Assessment of renal autoregulation
Am J Physiol Renal Physiol, April 1, 2007; 292(4): F1105 - F1123.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
A. T. Layton, L. C. Moore, and H. E. Layton
Multistability in tubuloglomerular feedback and spectral complexity in spontaneously hypertensive rats
Am J Physiol Renal Physiol, July 1, 2006; 291(1): F79 - F97.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
D. J. Marsh, O. V. Sosnovtseva, K. H. Chon, and N.-H. Holstein-Rathlou
Nonlinear interactions in renal blood flow regulation
Am J Physiol Regulatory Integrative Comp Physiol, May 1, 2005; 288(5): R1143 - R1159.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
D. J. Marsh, O. V. Sosnovtseva, A. N. Pavlov, K.-P. Yip, and N.-H. Holstein-Rathlou
Frequency encoding in renal blood flow regulation
Am J Physiol Regulatory Integrative Comp Physiol, May 1, 2005; 288(5): R1160 - R1167.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
D. R. Oldson, L. C. Moore, and H. E. Layton
Effect of sustained flow perturbations on stability and compensation of tubuloglomerular feedback
Am J Physiol Renal Physiol, November 1, 2003; 285(5): F972 - F989.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
H. E. Layton, E. B. Pitman, and L. C. Moore
Limit-cycle oscillations and tubuloglomerular feedback regulation of distal sodium delivery
Am J Physiol Renal Physiol, February 1, 2000; 278(2): F287 - F301.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
H. E. Layton, E. B. Pitman, and L. C. Moore
Spectral properties of the tubuloglomerular feedback system
Am J Physiol Renal Physiol, October 1, 1997; 273(4): F635 - F649.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online