AJP - Renal Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Renal Physiol 288: F605-F613, 2005; doi:10.1152/ajprenal.00171.2004
0363-6127/05 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (21)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Venturoli, D.
Right arrow Articles by Rippe, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Venturoli, D.
Right arrow Articles by Rippe, B.

INVITED REVIEW

Ficoll and dextran vs. globular proteins as probes for testing glomerular permselectivity: effects of molecular size, shape, charge, and deformability

Daniele Venturoli and Bengt Rippe

Department of Nephrology, University Hospital of Lund, Lund, Sweden

Polydisperse mixtures of dextran or Ficoll have been frequently used as molecular probes for studies of glomerular permselectivity because they are largely inert and not processed (reabsorbed) by the proximal tubules. However, dextrans are linear, flexible molecules, which apparently are hyperpermeable across the glomerular barrier. By contrast, the Ficoll molecule is almost spherical. Still, there is ample evidence that Ficoll fractional clearances (sieving coefficients) across the glomerular capillary wall (GCW) are markedly higher than those for neutral globular proteins of an equivalent in vitro Stokes-Einstein (SE) radius. Physical data, obtained by "crowding" experiments or measurements of intrinsic viscosity, suggest that the Ficoll molecule exhibits a rather open, deformable structure and thus deviates from an ideally hard sphere. This is also indicated from the relationship between (log) in vitro SE radius and (log) molecular weight (MW). Whereas globular proteins seem to behave in a way similar to hydrated hard spheres, polydisperse dextran and Ficoll exhibit in vitro SE radii that are much larger than those for compact spherical molecules of equivalent MW. For dextran, this can be partially explained by a high-molecular-size asymmetry. However, for Ficoll the explanation may be that the Ficoll molecule is more flexible (deformable) than are globular proteins. An increased compressibility of Ficoll and an increased deformability and size asymmetry for dextran may be the explanation for the fact that the permeability of the GCW is significantly higher when assessed using polysaccharides such as Ficoll or dextran compared with that obtained using globular proteins as molecular size probes. We suggest that molecular deformability, besides molecular size, shape, and charge, plays a crucial role in determining the glomerular permeability to molecules of different species.

capillary permeability; polysaccharides; macromolecules; reflection coefficient; transport



Address for reprint requests and other correspondence: B. Rippe, Dept. of Nephrology, Univ. Hospital of Lund, S-211 85 Lund, Sweden (E-mail: Bengt.Rippe{at}njur.lu.se)




This article has been cited by other articles:


Home page
Biophys. JHome page
A. B. Goins, H. Sanabria, and M. N. Waxham
Macromolecular Crowding and Size Effects on Probe Microviscosity
Biophys. J., December 1, 2008; 95(11): 5362 - 5373.
[Abstract] [Full Text] [PDF]


Home page
J. Physiol.Home page
J. N. Edwards and B. S. Launikonis
The accessibility and interconnectivity of the tubular system network in toad skeletal muscle
J. Physiol., November 1, 2008; 586(21): 5077 - 5089.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
Z. Liu, W. Weng, R. M. Bookchin, V. L. Lew, and F. A. Ferrone
Free Energy of Sickle Hemoglobin Polymerization: A Scaled-Particle Treatment for Use with Dextran as a Crowding Agent
Biophys. J., May 1, 2008; 94(9): 3629 - 3634.
[Abstract] [Full Text] [PDF]


Home page
Physiol. Rev.Home page
B. Haraldsson, J. Nystrom, and W. M. Deen
Properties of the Glomerular Barrier and Mechanisms of Proteinuria
Physiol Rev, April 1, 2008; 88(2): 451 - 487.
[Abstract] [Full Text] [PDF]


Home page
Mol. Pharmacol.Home page
N. P. Barrera, J. Betts, H. You, R. M. Henderson, I. L. Martin, S. M. J. Dunn, and J. M. Edwardson
Atomic Force Microscopy Reveals the Stoichiometry and Subunit Arrangement of the {alpha}4{beta}3{delta} GABAA Receptor
Mol. Pharmacol., March 1, 2008; 73(3): 960 - 967.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
A. H. J. Salmon, I. Toma, A. Sipos, P. R. Muston, S. J. Harper, D. O. Bates, C. R. Neal, and J. Peti-Peterdi
Evidence for restriction of fluid and solute movement across the glomerular capillary wall by the subpodocyte space
Am J Physiol Renal Physiol, December 1, 2007; 293(6): F1777 - F1786.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
W. H. Fissell, S. Manley, A. Dubnisheva, J. Glass, J. Magistrelli, A. N. Eldridge, A. J. Fleischman, A. L. Zydney, and S. Roy
Ficoll is not a rigid sphere
Am J Physiol Renal Physiol, October 1, 2007; 293(4): F1209 - F1213.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
C. Rippe, A. Rippe, A. Larsson, D. Asgeirsson, and B. Rippe
Nature of glomerular capillary permeability changes following acute renal ischemia-reperfusion injury in rats
Am J Physiol Renal Physiol, December 1, 2006; 291(6): F1362 - F1368.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
D. Asgeirsson, D. Venturoli, B. Rippe, and C. Rippe
Increased glomerular permeability to negatively charged Ficoll relative to neutral Ficoll in rats
Am J Physiol Renal Physiol, November 1, 2006; 291(5): F1083 - F1089.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Cell Physiol.Home page
W. Yu, R. M. Sandoval, and B. A. Molitoris
Quantitative intravital microscopy using a Generalized Polarity concept for kidney studies
Am J Physiol Cell Physiol, November 1, 2005; 289(5): C1197 - C1208.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2005 by the American Physiological Society.