AJP - Renal Add DOIs to your references at manuscript stage!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Renal Physiol 296: F1258-F1265, 2009. First published February 11, 2009; doi:10.1152/ajprenal.90638.2008
0363-6127/09 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
296/6/F1258    most recent
90638.2008v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Google Scholar
Right arrow Articles by Tanner, G. A.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tanner, G. A.

Glomerular sieving coefficient of serum albumin in the rat: a two-photon microscopy study

George A. Tanner

Department of Cellular and Integrative Physiology, Indiana University School of Medicine, Indianapolis, Indiana

Submitted 25 October 2008 ; accepted in final form 4 February 2009

Recent studies of the sieving of serum albumin in the rat kidney using a two-photon microscope suggested that the glomerular sieving coefficient (GSC) of albumin is 0.034, much higher than earlier micropuncture determinations. In the present study, we critically evaluated the use of the two-photon microscope to measure the GSC of albumin in the Munich-Wistar rat in vivo. The albumin GSC averaged 0.004 (SD 0.004), n = 34 glomeruli, when determined with a Zeiss two-photon microscope system and 0.002 (SD 0.002), n = 5, when determined with an Olympus two-photon microscope system. These values are close to the lower limit of detection of GSC, which we estimate to be ~0.001–0.003. We identified several factors that were likely responsible for the higher albumin GSCs reported earlier using two-photon microscopy. These include animal conditions (i.e., low glomerular filtration rate) and failure to recognize the role of out-of-focus fluorescence in contaminating the fluorescence signal from the urinary space of Bowman's capsule. We observed that hypothermia plus dehydration or a low blood pressure led to an increased albumin GSC. High levels of illumination (high laser outputs) resulted in a falsely elevated albumin GSC. Use of external, instead of internal, photodetectors resulted in an exaggerated albumin GSC because of greater collection of out-of-focus fluorescence. In conclusion, the albumin concentration in the glomerular filtrate of the normal rat, determined by two-photon microscopy, is exceedingly low (5–10 mg/dl).

glomerular permeability; multiphoton microscopy; rat kidney



Address for reprint requests and other correspondence: G. A. Tanner, Dept. of Cellular and Integrative Physiology, Indiana Univ. School of Medicine, 635 Barnhill Drive, MS 332, Indianapolis, IN 46202 (e-mail: gtanner{at}iupui.edu)







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2009 by the American Physiological Society.