|
|
||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1Department of Physics, The Technical University of Denmark, Kongens Lyngby, Denmark; 2Department of Physics, Saratov State University, Saratov, Russia; 3Department of Physiology and Biophysics, University of South Florida School of Medicine, Tampa, Florida; 4Department of Medical Physiology, University of Copenhagen, Copenhagen, Denmark; and 5Department of Molecular Pharmacology, Physiology, and Biotechnology, Brown University, Providence, Rhode Island
Submitted 2 February 2007 ; accepted in final form 28 August 2007
| ABSTRACT |
|---|
|
|
|---|
tubuloglomerular feedback; myogenic mechanism; oscillations; wavelet analysis
The limit cycle oscillation in TGF arises because of a relatively high feedback gain connected with a number of nonlinearities and delays in the system.1 Mass epithelial transport of Na and Cl, particularly in the thick ascending limbs of Henle's loop (12, 20), the dependence of the tubular feedback signal on flow rate of tubular fluid, the effect of tubular compliance on fluid wave propagation velocity (38), signal propagation from the macula densa to vascular smooth muscle cells in the afferent arteriole, and the outflow resistance into the distal tubule (12, 27) all contribute to the aggregate delay. We have suggested that the myogenic oscillation arises from nonlinear interactions among voltage and Ca-sensitive K channels and voltage-gated Ca channels in the plasma membrane of vascular smooth muscle cells (29). The TGF and myogenic mechanisms interact because they share a common contractile machinery in vascular smooth muscle cells (29).
Interactions of nonlinear oscillators can give rise to a number of phenomena, such as amplitude and frequency modulation, synchronization, and transitions to chaos. This last phenomenon is of particular interest, because our laboratory has shown that tubular pressure fluctuations in rats with renovascular or genetic hypertension are irregular (10, 52, 54, 55). Power spectra derived from such records show power distributed over a broad frequency band, and the data have characteristics of deterministic chaos (54, 55). Tubular pressure fluctuations from neighboring nephrons of hypertensive rats appear to synchronize (52); synchronization of chaotic systems is also well known (32, 34).
The problem at hand is to test for the presence and the durability of interactions in the systems providing renal blood flow regulation. Previous work on this problem has concentrated on interactions between the TGF and myogenic modes in single nephrons and has made use of whole kidney blood flow measurements (2), tubular pressure measurements from stop-flow (3, 36) and free-flow experiments (41, 43), or single-nephron blood flow (29). We reported previously that the sensitivity of myogenic oscillations to the activity of the TGF mode is much stronger in hypertensive rats (43), a conclusion in agreement with that of Raghavan et al. (36), who analyzed TGF myogenic interactions in stop-flow experiments in single nephrons.
None of these approaches measured synchronization between nephrons, and none analyzed the TGF-myogenic interaction in the context of nephron synchronization, in either normotensive or hypertensive rats. In this study, we present results from the systematic quantitative analysis of free-flow tubular pressure recorded from paired sets of nephrons (52) using wavelet transforms, which are analytic techniques (42) more sophisticated than those available when the experimental recordings were first published. Wavelet analysis enabled us to assess both frequency adjustments and phase synchronization as independent measures of interactions. The nephrons were positively identified as having arisen from single cortical radial arteries and were therefore able to exchange signals because of their vascular proximity (1, 8, 16, 48, 52). The data sets included results from both normotensive and spontaneously hypertensive rats (SHR).
Because each nephron has both TGF and myogenic oscillations, a form of synchronization between neighboring nephrons may occur in which both TGF and the myogenic mechanisms show frequency and phase adjustments and the two nephrons achieve an overall 1:1 synchronization for both the TGF and the myogenic modes, a state we shall refer to as bimodal synchronization. Alternatively, there may be states of partial synchronization, in which some of the rhythmic components synchronize, but others do not. We found bimodal synchronization between nephrons to be typical of normotensive rats and partial synchronization more characteristic of hypertensive rats. The partial synchronization of hypertensive rats can involve either the myogenic oscillations of the neighboring nephrons alone or the TGF oscillations alone. The result with hypertensive rats is counterintuitive, because nephron connection strength is greater in hypertensive than in normotensive rats (1, 5, 23, 48).
The significance of these observations is that synchronization among oscillating units can form the basis of self-organized ensembles that act as a coherent whole. Synchronization at discrete frequencies among neurons in different regions of the brain is now well known as the basis for a good deal of integrated neuronal activity (39). What an ensemble of synchronized nephrons might be able to achieve is not presently known, but it is noteworthy that the synchronization is less complete in hypertension, a disease state in which the ability to excrete Na is known to be problematic.
| METHODS |
|---|
|
|
|---|
Tubular pressure data were recorded through a low-pass Butterworth filter with a cutoff frequency of 1.5 Hz. The data records, which varied in length from 240 to 1,260 s, were then digitized. The rate of digitization was varied, depending on the length of the recording, to produce records with 4,096 points in each of the paired samples. The respiratory signal was removed with a Kaiser-Bessel low-pass filter with a cutoff frequency of 0.5 Hz and attenuation of 50 dB. The calculations reported in this paper were performed on the output of the Kaiser-Bessel filter.
Data analysis. Because of the presence of a number of different modes, the renal tubular pressure signals, like other physiological signals, should be expected to be both inhomogeneous and nonstationary. The results of Raghavan et al. (36) conform to this description. Techniques based on wavelet analysis are widely used to analyze problems of this sort (4, 7, 26, 46, 47). Wavelets provide a tool for detecting periodicities in short, nonstationary data and for following the temporal evolution of different rhythmic components in the case of noisy multimode dynamics.
The wavelet transform (W) of a signal x(t) can be written as:
![]() | (1) |
(
) is referred to as the "mother" function;
a,b =
[(t – b)/a] is a translated and scaled version of this function, with a and b characterizing the time scale and temporal localization, respectively; the asterisk refers to the complex conjugate; and x(t) is the time series. To detect the presence of various rhythmic components, the Morlet-wavelet is particularly useful. The simplified expression of this wavelet has the form:
![]() | (2) |
In addition to the wavelet transform coefficients Wx(a,b) [or Wx(f,b)], the power spectral density Ex(f,b)
Wx(f,b)2 can be estimated. The result is a surface in three-dimensional space Ex(f,b) whose sections at fixed time moments b = t0 correspond to the local power spectrum. To simplify the visualization of this surface, only the dynamics of the local maxima of Ex(f,b), the time evolution of the spectral peaks, are estimated (15). This approach allows us to extract the time dependencies of the instantaneous frequencies for the rhythmic components of the signal.
For the analysis of the temporal variation of the proximal tubular pressure in adjacent nephrons, one can distinguish four potential states of their interactive dynamics: 1) bimodal coherence when the instantaneous frequencies for both oscillatory modes remain close in time; 2) the completely incoherent state; and 3) the two states of partial entrainment where coherence is observed for only one of the oscillatory modes. An approach based directly on the frequency adjustment is simple and has a clear physical interpretation, but it cannot detect a phase shift between the oscillations of the two interacting nephrons.
Tubular pressure in SHR fluctuates irregularly and generates power spectra with many different peaks (52, 54). Because we apply wavelet transforms to such records in this study, it will be useful to describe some of the special problems that might arise and how we deal with them. The instantaneous frequency of TGF can change its value in time in SHR more than is usually found in normotensive rats. The standard power spectrum provides an average value for each frequency over the entire observation period; a single process that changes its frequency over the course of the observation can generate more than a single spectral peak, even though it has just one instantaneous frequency at each moment in time. The single process is easily identified with the wavelet transform, despite its variation in time. Thus the presence of spectral peaks in adjacent frequency bands in SHR does not imply that there are fluctuations at two frequencies at the same time.
Second harmonics of the TGF oscillation are easily identified in the wavelet transform process because they have a frequency twice that of the TGF fluctuation (higher order harmonics usually have negligible power), and synchronization of harmonics was not included in our analysis.
Phase synchronization provides an alternative measure of entrainment phenomena in interacting systems (34, 37). In an earlier paper (13), we studied phase relations between two signals using a Hilbert transform. This approach works well when the signal has a dominant rhythmic component, but not with the separate dynamics of different rhythmic activities. In this study, the multimode process has one clearly expressed rhythm, the slow TGF oscillation, whereas the signature of the myogenic rhythm in the proximal tubular pressure records is much weaker. A separate investigation of the two modes could perhaps be accomplished after band-pass filtering to extract the frequency ranges associated with each mode. However, the filtering process can cause many technical problems in the case of nonstationary dynamics, especially if the two modes are closely positioned in the frequency domain and in the presence of significant harmonics and combination frequencies. Problems of this type can sometimes be solved by using a sliding window analysis (45), but the case in which the modes synchronize remains intractable with this technique. The wavelet approach represents the most effective way to study the different aspects of multimode phase dynamics. Instantaneous phases can be introduced via the wavelet-transform coefficients as follows:
![]() | (3) |
x(f,b) depends on the mode being analyzed. Lachaux et al. (18) and Quiroga et al. (35) used the definition of phase in Eq. 3 to analyze synchronization properties in EEG signals. They studied phase relations over a range of values of f by fixing the frequency and considering how the phase differences change with b.
In general, the wavelet transform provides us with two-dimensional arrays of moduli Wx(f,b) and phase
x(f,b). This means that the notion of phase is defined for each frequency f at any fixed time moment b. When considering two processes x(t) and y(t), the wavelet transform allows us to calculate the phase differences
x(f,b) –
y(f,b) and various synchronization factors (35). In the case of clearly expressed multimode dynamics, we do not need to know the complete two-dimensional phase spectrum
x(f,b), because we are interested only in phases related to the characteristic rhythmic contributions. If the instantaneous frequencies demonstrate large fluctuations relative to the mean value, it is useful to adjust the central frequency of the wavelet function according to these fluctuations. Hence we will modify slightly the approach considered in Refs. 18 and 35. We follow the time evolution of each mode in the frequency domain, and, at fixed moments of time b = t0, we extract the phases related to the local peaks of the power spectrum Ex(f,t0). For coupled nephrons, this permits introduction of the phase for the slow and the fast dynamics separately.
For two interacting self-sustained systems, synchronization manifests itself as an adjustment of their basic frequencies to satisfy the relation nf1 = mf2. In our analysis, we have restricted the values of the integers m and n to 10 or less, so as to consider only simple resonances. Another manifestation of synchronization is a phase adjustment in the interacting systems. The condition of phase synchronization may be expressed as:
![]() | (4) |
1 – m
2 = 
is the relative phase difference;
k, k = 1,2 are phases of signals 1 and 2;
< 2
is the limit used to define synchronization, as discussed below; and C is a constant whose value is chosen so that 
= 0 at t = 0. All subsequent estimated values of 
are relative to that initial value. If interacting systems are periodic and subject to noise, chaotic, or both, Eq. 4 may only remain satisfied during a finite time interval (44). In this case, a regime is considered to be synchronous when the duration of the locking time, the region over which Eq. 4 is satisfied, exceeds some predefined number of basic oscillatory periods (25). We took the predefined number to be the duration of eight periods of a particular oscillation, which translates to 250 s for the slow oscillations and 50 s for the fast. Results are presented as means ± 1 SE. Statistical significance was estimated using the Mann-Whitney test.
| RESULTS |
|---|
|
|
|---|
|
0.03 Hz, corresponding to the slow TGF-mediated oscillations and a wider peak from the myogenic mechanism in the range 0.10–0.20 Hz. The same peaks can be detected in the data from hypertensive rats, although they are significantly smaller and broader, reflecting the irregularity of the signal. These results were obtained by calculating single power spectra from each experimental time series and averaging all of the power spectra in each group of animals, a method that provides no temporal resolution.
|
|
|
Interactions between TGF and myogenic oscillations in single nephrons. We first consider the case of intranephron interaction of the two modes. Figure 4 shows distributions of the ratio ffast(t)/fslow(t), where fslow(t) and ffast(t) are the frequencies of the TGF-mediated and the myogenic oscillations, respectively. The distribution obtained for normotensive rats, shown in Fig. 4A, has two peaks corresponding to the ratios 4 and 5. This implies that the fast and the slow components adjust their periods in such a way as to maintain a near 4:1 or 5:1 entrainment during significant parts of the observation time. The shoulder on the left-hand side of the 5:1 indicates the presence of intervals with 6:1 synchronization. For the chaotic oscillations observed for the hypertensive rats, shown in Fig. 4B, the frequency ratio changes more randomly in time. There is only a single broad peak in the probability density, and the nephron dynamics show mutual adjustments only for time intervals that are too short to be clearly expressed in the averaged distribution of the ratio ffast(t)/fslow(t). Examples illustrating how this ratio changes in time were presented by Sosnovtseva et al. (42).
|
Synchronization of interacting nephrons. Vascular casts were used to test whether pairs of superficial nephrons used for tubular pressure measurements had afferent arterioles branching from a single cortical radial artery (52). We shall refer to those pairs that had origins from the same cortical radial artery as neighboring nephrons. Figure 5 illustrates two different synchronization states that can occur in a pair of neighboring nephrons. In Fig. 5A, the ratio f1(t)/f2(t) between the frequencies in the two nephrons remain close to 1:1 throughout the observed time interval for both the slow and the fast modes. One can observe some fluctuation in the frequency ratio, particularly for the fast modes, but the amplitude of this fluctuation remains within a limit of ±10% of the nominal frequency. In Fig. 5B, on the other hand, the only synchronization between the two nephrons is in the slow mode. The frequency ratio of the fast mode varies over the time course of the experiment, exceeding the 10% limit for more than one-half the observation time and does not settle at a plateau at or near 1.00. Figure 5B illustrates a case of partial synchronization.
|
As shown in Table 2, there is a difference in synchronization phenomena between the normotensive and the hypertensive rats. Nephrons of normotensive rats supplied from the same cortical radial artery are fully coherent 81% of the time, where both the slow and the fast oscillations synchronize, as seen in Fig. 5A. The other combinations of possible dynamics have a significantly lower probability of occurrence. In contrast, the most probable state for the hypertensive rats is one of partial synchronization, where either the slow or the fast rhythms are locked while the other mode remains nonsynchronous, as seen in Fig. 5B. The slow mode locks more frequently than the fast mode.
|
30% of remaining synchronized for more than 50 s, corresponding to eight periods of the myogenic oscillations, while for hypertensive rats this probability is only 12%. Slow oscillations in normotensive rats are three to four times as likely to display long locking times as in SHR, and a similar factor applies to the fast oscillations.
|
We also analyzed data from paired nephrons that were found to originate from different cortical radial arteries. In these measurements, we expected to find no interaction because of the origin from different cortical radial arteries, and visual inspection of the original data confirms this expectation (52). For normotensives, the slow oscillation had a mean locking time of 48 ± 5 s and the fast oscillation 27 ± 4 s; for hypertensives, the corresponding findings were 42 ± 6 s and 15 ± 2 s. The estimated locking time of these TGF oscillations is less than two full periods. The results confirm the prediction and also the specificity of the analytic methods.
Phase entrainment of interacting nephrons.
Frequency and phase synchronization are useful alternate approaches to evaluating entrainment phenomena in coupled systems (34, 37). The two approaches are not identical, because frequency synchronization characterizes the average behavior of a system over some time interval, while phase synchronization describes the system at each time moment and provides additional information on phase shifts. For chaotic and stochastic systems, these two approaches can give different results. As in the case of frequency adjustments, we need to formulate the conditions under which the dynamics can be considered as synchronous. For 1:1 synchronization, this condition should ensure that the modulus of the phase difference between the oscillations in the paired nephrons does not exceed some fixed value
. Here, we have chosen
= 2
/10 for the slow rhythm and
= 2
/6 for the fast mode. The time series we analyzed are neither stationary nor free of noise, and these factors can cause some variability in the phase-angle difference. The values of
we chose allow for some variability from these sources. The different values of
account for a significantly higher variability of the myogenic oscillations. The duration of the mean locking time, our measure of the degree of synchronization, depends on the condition applied to the parameter
, but, even with different conditions for
, the qualitative synchronous patterns remain the same.
Figure 7A shows variations of the normalized phase difference for the regular pressure dynamics in a normotensive rat; the synchronization of the slow and the fast oscillations for nephrons branching from the same cortical radial artery is apparent. Nephron dynamics of a hypertensive rat, shown in Fig. 7B, are more complicated, especially with respect to entrainment of the myogenic components. It is possible to find examples where the fast modes demonstrate segments of phase-locked oscillations, although a more typical case is when the phase-locked regime occurs only for short time intervals. Figure 7B illustrates partial entrainment because only the slow mode demonstrates intervals of phase-locked dynamics for a longer duration than a single period of the slow oscillations, which is
30 s.
|
|
| DISCUSSION |
|---|
|
|
|---|
Chon et al. (2) used Volterra-Wiener kernels to estimate interactions between TGF and the myogenic mechanism in whole kidney blood flow records with arterial pressure subject to white noise forcing. They detected nonlinear interactions in normotensive animals, but not in hypertensives. Using bispectrum analysis of tubular pressure measurements from stop-flow experiments, Chon et al. subsequently confirmed the presence of nonlinear interactions between TGF and the myogenic mechanism in normotensive but not in hypertensive animals (3). They speculated that the failure to detect interactions in hypertensives was a defect of the time-invariant bispectral technique. They, therefore, developed a time-varying bispectrum approach and used it to show that nonlinear interactions between TGF and the myogenic mechanism did occur in hypertensive animals, but that the interactions were shorter lived than in normotensives (36). Our analysis of the interaction between the myogenic and TGF modes from free-flow tubular pressure recordings confirms these earlier results, despite the different experimental settings from which the data were collected.
We evaluated synchronization phenomena in interacting nephrons by measuring both frequency and phase synchronization. Statistical analyses performed with these two techniques showed that completely nonsynchronous dynamics are atypical for nephrons of normotensive rats supplied by a common cortical radial artery; the probability of this state ranges from 1 to 5%, depending on whether frequency or phase is assessed. The completely nonsynchronous regime occurs more frequently in the dynamics of the SHR (15–24%). Normotensive rats demonstrate full entrainment in which both oscillatory modes are synchronized; the probability in both tests exceeds 70%. SHR demonstrate a different type of internephron dynamics: partial entrainment where neighboring nephrons attain a state of synchronization with respect to their slow dynamics, but the fast dynamics remain desynchronized, or vice versa. The aggregate probability of partial entrainment exceeds 40% in SHR. SHR generally are in a synchronous state for only one-third to one-half as long as the normotensive ones; they have about one-half the probability of full synchronization and about twice the probability of partial synchronization.
The physiological mechanisms responsible for the various synchronization phenomena we have characterized are largely unknown. We have suggested that the coupling of TGF to the myogenic mechanism takes place in vascular smooth muscle cells and makes use of voltage-gated Ca channels (29), but other coupling routes are possible. Coupling via plasma membrane Ca channels leads to the prediction that the TGF oscillation modulates both the amplitude and the frequency of the myogenic oscillation; analyses of single nephron blood flow data and the results of this study confirm the prediction (31). The modulation of the myogenic mechanism by TGF has been observed in the isolated, perfused juxtamedullary preparation (49). There is also accumulating evidence that nitric oxide modulates the TGF-myogenic interaction (14, 15, 40, 51).
The conduction mechanism for nephron-to-nephron signaling has been subject to very little investigation. Recent work by Peti-Peterdi (33) suggests that a propagated Ca wave is too slow to account for signal conduction, leaving electrotonic conduction as the most likely explanation.
Oscillations such as those we analyzed arise naturally from the operation of nonlinear systems. The interaction of such self-sustained systems can lead to different nonlinear outcomes, including synchronization, amplitude and frequency modulation, and chaos (32). Whether interacting nonlinear oscillators achieve synchronization is a question that arises in many areas of science (32, 34); its functional meaning in renal physiology remains to be discovered. Synchronization of self-sustaining oscillations can permit the ensemble of synchronized units, in this case nephrons, to react in a coordinated fashion to perturbations of the system. Such self-organized systems can take on emergent properties, and, in living systems capable of adaptation, it is natural to assume that the oscillations are system responses designed specifically to generate the emergent functional properties. We suggest that nephron synchronization provides the basis for self-organized action in response to naturally occurring fluctuations in blood pressure (9). Below we discuss one possible aspect of self-organization in the kidney.
Tubular pressure recordings from rats with hypertension show characteristics of deterministic chaos (54, 55). These characteristics include a positive Lyapunov exponent indicating high sensitivity to initial conditions, a hallmark of chaotic systems, and a low-dimension noninteger phase space attractor (54). The data also pass a test known as surrogate data analysis (55). The test is designed to determine whether noise is responsible for the irregular fluctuations in the signal; when applied to renal tubular pressure records, the test result showed little indication of noise as a factor. Bifurcations to chaos in model systems can occur in a single nonlinear system when the value of the parameter is made to exceed a critical value, or when the coupling strength of an ensemble of nonlinear systems is increased above a critical value. The measured value of TGF gain is almost twice normal in SHR (5, 10), and the coupling strength of nephron-nephron interactions is increased threefold (1, 48). Thus the conditions required for a bifurcation to chaos are present in SHR, and we (30) and Layton et al. (19) have shown in different simulations that the connection strength of internephron coupling can serve as a bifurcation parameter. Although chaotic systems are known to synchronize (32, 34), it is also true that the synchronization is more easily disrupted than when the same nonlinear systems are oscillating (24). From these considerations, we speculate that the increase in the strength of both intra- and internephron coupling is the initial event in the partial disruption of nephron synchronization we observed. It remains to be determined what adaptive purpose, if any, is served by the increase in connection strengths and the bifurcation to chaos in hypertension.
We suggest that the less frequent synchronization we found in SHR could have at least two sets of functional consequences. First, consider the effects on blood flow distribution. We recently simulated the interactions among oscillating nephrons of different lengths supplied by a single cortical radial artery that could be synchronized by vascular signals (30). With no vascular coupling, the simulation showed that the fraction of cortical radial artery blood flow received by each nephron varied with time because the oscillations were not synchronized. Vascular coupling produced synchronization of nephrons and an oscillation of mean vascular pressure in the cortical radial artery, and the fractional delivery of blood to each nephron remained constant throughout the TGF cycle. The results of this study suggest that, because of decreased synchronization, fractional blood flow distribution among nephrons of SHR will be more highly variable, an effect that could cause more highly variable GFR. Episodes of elevated GFR from this source could contribute to impaired regulation of solute excretion and to glomerular damage.
A second consequence of imperfect synchronization among nephrons will likely be irregular delivery of tubular fluid to distal nephron segments. We have found oscillations in distal tubule pressure and of distal tubule Cl concentration at the TGF frequency (11), indicating that fluid delivery to distal segments retains some of the dynamic properties of nephron blood flow and GFR. Cortical collecting tubules and inner medullary collecting ducts receive tubular fluid from a number of nephrons. It is likely that the dynamics of fluid delivery to these tubular junctions will depend on the dynamics of blood flow and GFR regulation; if nephron blood flows are synchronized, so too will be distal delivery. Noncoherent blood flow regulation among nephrons is likely to cause noncoherent delivery into collecting tubules and ducts. At stake here are flow-dependent K secretion and hormone-dependent reabsorption of Na, Cl, and other ions. Modern understanding of these processes is described only as if the flows remain steady in time. The steady-state formulation is equivalent to an assumption that flow rates in all distal tubules feeding a cortical collecting duct are synchronized. In the absence of synchronization, or if synchronization is intermittent, flow and solute load-dependent processes may not generate time average values equivalent to tubules operating in a steady state. It remains to be seen whether these effects, if they do occur, have functional consequences.
| GRANTS |
|---|
|
|
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
1 Nonlinear systems that are second order or higher and that combine an unstable (focus) equilibrium point with dissipative terms can sustain oscillations that return to a stable periodic orbit when perturbed. These periodic orbits are known as limit cycle oscillations. Physiological systems need to respond to perturbations and are invariably dissipative. The transition in which the equilibrium point turns into an unstable focus is a Hopf bifurcation. ![]()
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
K. L. Siu, B. Sung, W. A. Cupples, L. C. Moore, and K. H. Chon Detection of low-frequency oscillations in renal blood flow Am J Physiol Renal Physiol, July 1, 2009; 297(1): F155 - F162. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Marsh, I. Toma, O. V. Sosnovtseva, J. Peti-Peterdi, and N.-H. Holstein-Rathlou Electrotonic vascular signal conduction and nephron synchronization Am J Physiol Renal Physiol, April 1, 2009; 296(4): F751 - F761. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Iliescu, R. Cazan, G. R. McLemore Jr., M. Venegas-Pont, and M. J. Ryan Renal blood flow and dynamic autoregulation in conscious mice Am J Physiol Renal Physiol, September 1, 2008; 295(3): F734 - F740. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |